This method retrieves the possible setting values for a specified property of the scan device.
Parameters
Name | Explanation |
---|---|
CapNo | The number for the retrieved property (in
hexidecimal)
0x0100 Compression method 0x0101 Pixel type 0x0102 Scan units of measurement 0x0103 Method of transfer 0x1101 Brightness 0x1103 Contrast 0x1108 Gamma 0x1109 Halftone 0x110a Highlight 0x110c File Format 0x110e Dropout color 0x1110 Paper orientation 0x1113 Shadow 0x1118 Horizontal resolution 0x1119 Vertical resolution 0x1121 Rotation angle 0x1122 Paper size 0x1123 Threshold 0x1124 Horizontal scaling 0x1125 Vertical scaling 0x112c Method of color reduction 0x1147 Image filter 0x1148 Noise filter 0x1149 OverScan 0x1153 JPEG quality coefficient 0xf001 Scanning speed 0xf002 Moire filter 0xf004 Sharpness 0xf006 Extended UiMode 0xf007 Dynamic threshold 0xf00b Skip blank page 0xf00e Text enhancement In Visual Basic, replace 0x with &H.
In Visual Basic the following constants can be used: (ikScanCompression = 0x0100, ikScanPixelType = 0x0101, ikScanUnits = 0x0102, ikScanTransferMode = 0x0103, ikScanFeederEnabled = 0x1002, ikScanFeederLoaded = 0x1003, ikScanIndicator = 0x100b, ikScanUiControllable = 0x100e, ikScanDeviceonline = 0x100f, ikScanThumbnailsEnabled = 0x1011, ikScanDuplex = 0x1012, ikScanEnableDSUIOnly = 0x1014, ikScanCustomDSData = 0x1015, ikScanBrightness = 0x1101, ikScanContrast = 0x1103, ikScanGamma = 0x1108, ikScanHalfTone = 0x1109, ikScanHighlight = 0x110a, ikFileScanFormat = 0x110c, ikScanDropoutColor = 0x110e, ikScanOrientation = 0x1110, ikScanShadow = 0x1113, ikScanXResolution = 0x1118, ikScanYResolution = 0x1119, ikScanRotation = 0x1121, ikScanPaperSize = 0x1122, ikScanThreshold = 0x1123, ikScanXScaling = 0x1124, ikScanYScaling = 0x1125, ikScanBitDepthReduction = 0x112c, ikScanUndefinedImagesize = 0x112d, ikScanImageDataset = 0x112e, ikScanImageFilter = 0x1147, ikScanNoiseFilter = 0x1148, ikScanOverScan = 0x1149, ikScanBorderDetection = 0x1150, ikScanDeskew = 0x1151, ikScanJpegQuality = 0x1153, ikScanScanningSpeed = 0xf001, ikScanMoirefilter = 0xf002, ikScanMoirefilterMaxResolution = 0xf003, ikScanSharpness = 0xf004, ikScanRotateBack = 0xf005, ikScanExtUiMode = 0xf006, ikScanDynamicThreshold = 0xf007, ikScanPixelAutomationCap = 0xf008, ikScanMultiStream = 0xf009, ikScanTextOrientationRecognition = 0xf00a, ikScanSkipBlankPage = 0xf00b, ikScanRemoveHole = 0xf00c, ikScanFocusPosition = 0xf00d, ikScanTextEnhancement = 0xf00e). |
ConType | A variable that contains the type of the retrieved property value (see below) |
List | An array containing the retrieved values (Use when
CapNo refers to properies other than halftone)
Visual C++: pass the pointer to the first element in the array Visual Basic: If Dim List(0 To 2) As Single, then the arguments are returned in the first element of the array List(0). |
CurrentIndex |
The index referring to the current value of the List (the index starts from 0) List[CurrentIndex] = current value |
DefaultIndex | The index referring to the default value of the
List (the index starts from 0)
List[DefaultIndex] = default value |
ListNum | The number of elements in the List array |
Return Value
- When the CapNo refers to halftone
- Returns the retrieved number of halftone.
- When the CapNo refers to settings other than halftone
- If ConType=3 or 4, then the number is retrieved
If ConType=5 then 1 is returned, if ConType=6 then 5 is returned (these are constants).
If List is NULL or ListNum is 0 then the number of elements in the appropriate array are returned.
If 0 is returned then there was an error. Please refer to the error status.
Explanation
The GetCapEnum method retrieves the possible setting values for a specified property of the scan device. To retrieve the possible setting values for a property it is first necessary to set the DsName property. If the DsName property is blank then please execute the Select method prior to executing the GetCapEnum method. (Note: If the OpenDS method is executed prior to the GetCapEnum method the the DsName property is disabled and the open datasource is used). If the CapNo refers to halftone, then the List array is not used, however you must pass a dummy array or NULL into the List parameter. ListNum is also not used in this case so please set it to 0.
Depending on the scanner being used, it is possible that the range acceptable resolution values will differ according to the pixel type setting (1 bit color or 24 bit color). Also, depending on the type of transfer mode used (memory or file), the type of compression values possible may differ. Because of this, before retreiving the range of possible XDpi and YDpi values, you should first set the PixelType property and before retrieving the possible compression values, you should first set the TransferMode property.
To execute the GetCapEnum method you must first execute the Initialize method. If the OpenDS method is executed prior to executing the GetCapEnum method then the open datasource cannot be used by another application until that datasource (scan device) is closed.
For scripting languages and other programs that require variant types, please refer to the GetCapEnumVariant method.
The GetCapEnum method corresponds to the Scan Control's ScanGetCapEnum method in earlier versions of the ImageKit.
Regarding ConType values
(0: When False (0) is returned, 3: when an array is returned, 4 when a list is returned, 5: when a single value is returned, 6: when a range is returned)
- When CapNo refers to HalfTone
- If ConType=3, then the HalfToneList property value is set
and CurrentIndex and DefaultIndex are disabled.
If ConType=4, then the HalfToneList property value is set.
If ConType=5, then the HalfToneList property value is set to the current (default) value.
If ConType=6, then no halftone is available - When CapNo refers to something other than HalfTone
- If ConType=3, then the values of the List array are set and
CurrentIndex and DefaultIndex are disabled.
If ConType=4, then the values of the List array are set.
If ConType=5, then the current (default) value is set in the first element, List[0], of the List array.
If ConType=6, then minimum value is set in the first element, List[0], of the List array; the maximum value is set in the second element, List[1], the step value is set in the third element, List[2], the default value is set in the fourth element, List[3], and the current value is set in the fifth element, List[4].
Regarding the values set into the List array
- When CapNo refers to the compression method:
- 0: uncompressed, 1: PACKBITS, 2: GROUP3-1D, 3: GROUP3-1DEOL, 4: GROUP3-2D, 5: GROUP4, 6: JPEG, 7: LZW, 8: JBIG, 9:PNG, 10: RLE4, 11: RLE8, 12: BITFIELDS (2, 3, 4, 5 are FAX[CCITT], 10, 11, and 12 are BMP)
- When CapNo refers to PixelType:
- 0: Black and White - (2 bits), 1: Grayscale, 2: RGB color, 3:
Palette color
(Depending on the datasource, values can also range from 4 to 8) - When CapNo refers to Scan Units:
- 0: Inches, 1: Centimeters, 2: Pica, 3: Points, 4: Twips, 5: Pixels, 6: Millimeters
- When CapNo refers to the method of transfer:
- 0: Native, 1: File, 2: Memory, 3: File2
- When CapNo refers to the file format:
- 0: TIFF, 1: PICT, 2: BMP, 3: XBM, 4: JFIF(JPEG), 5: FPX, 6: TIFF MULTI, 7: PNG, 8: SPIFF, 9: EXIF, 10: PDF, 11: JP2 (JPEG2000 Part1), 13: JPX(JPEG2000 Part2), 14: DEJAVU, 15: PDF/A(Version1), 16: PDF/A(Version2)
- When CapNo refers to the Dropout color:
- 0: Red, 1: Green, 2: Blue, 3:None, 4: White
(Depending on the datasource, values 5,6 can be set) - When CapNo refers to the orientation of the paper:
- 0: 0 degrees (Portrait), 1: 90 degrees, 2: 180 degrees, 3: 270 degrees (Landscape)
- When CapNo refers to paper size:
- 0: User defined size, 1: A4, 2: JIS B5, 3: US letter, 4: US legal, 5: A5, 6: ISO B4, 7: ISO B6, 9: US ledger, 10: US executive, 11: A3, 12: ISO B3, 13: A6, 14: C4, 15: C5, 16: C6, 17: 4A0, 18: 2A0, 19: A0, 20: A1, 21: A2, 22: A7, 23: A8, 24: A9, 25: A10, 26: ISO B0, 27: ISO B1, 28: ISO B2, 29: ISO B5, 30: ISO B7, 31: ISO B8, 32: ISO B9, 33: ISO B10, 34: JIS B0, 35: JIS B1, 36: JIS B2, 37: JIS B3, 38: JIS B4, 39: JIS B6, 40: JIS B7, 41: JIS B8, 42: JIS B9, 43: JIS B10, 44: C0, 45: C1, 46: C2, 47: C3, 48: C7, 49: C8, 50: C9, 51: C10, 52: US statement, 53: Business card, 54: Maximum size, 1000 Undefined
- When CapNo refers to reduction of color depth:
- 0: Threshold, 1: HalfTone, 2: Custom HalfTone, 3: Diffusion
- When CapNo refers to the noise filter:
- 0: None, 1: Automation, 2: LOWPASS, 3: BANDPASS, 4: HIGHPASS
- When CapNo refers to the image filter:
- 0: None, 1: Automation, 2: LONEPIXEL, 3: MAJORITYRULE
- When CapNo refers to the OverScan:
- 0: Uses the set scan size to scan, 1: Considers the scan size setting and automatically scans, 2: Uses the scan size setting as a base then increases the top and bottom dimensions to scan, 3: Uses the scan size setting as a base then increases the left and right dimensions to scan, 4: Uses the scan size setting as a base then increases the top, bottom, left, and right dimensions to scan
- When CapNo refers to the scanning speed:
- This is enabled only for certain Epson and Panasonic
scanners
(1) Epson Scan Drivers - 0: For Quality, 1: For Speed
(2) Panasonic Scan Drivers - 0: Slow, 1: Normal, 2: Fast - When CapNo refers to the moire filter:
- This is enabled only for certain Epson scanners, Canon DR
scanners, and PFU Scanners.
(1) Epson Scan Drivers - 0: None, 1: Standard, 2: 85lpi (For Newspapers), 3: 133lpi (for Magazines and Catalogs), 4: 175lpi (for Photographs)
(2) Canon DR Scan Drivers - 1: None, 2: High Speed Scanning, 3: High Quality Scanning
(3) PFU Scan Drivers - 0: None, 1: Moire Filter level1, 2: Moire Filter level2, 3: Moire Filter level3, 4: Moire Filter level4 - When CapNo refers to Sharpness:
- This is enabled only for certain Canon DR scanners, Epson
scanners, Panasonic scanners, and PFU scanners.
For Canon DR scanners it is known as "edge enhancement", for Epson scanners it is known as "unsharp mask", for Panasonic scanners it is known as "image quality", and for PFU scanners, it is know as "outline enhancement".
(1) Canon DR Scan Drivers - From 1 to 5
(2) Epson Scan Drivers - 0: None, 1: Small, 2: Medium (default), 3: Large
(3) Panasonic Scan Drivers - 0: None, 1: Smooth, 2: Low, 3: Standard, 4: High
(4) PFU Scan Drivers - 0: None (Default), 1: Weak outline enhancement, 2: Medium outline enhancement, 3: Strong outline enhancement - When CapNo refers to the Extended UiMode:
- This is enabled only for certain Epson scanners
0: Starts up the UI mode that was last used, 1: Starts up the professional mode, 2: Starts up the automatic mode, 3: Starts up the home mode, 4: Starts up the automatic mode (with no error messages and supressed UI), 5: Starts up office mode - When CapNo refers to the dynamic threshold:
- This is enabled only for certain Panasonic scanners
0: None, 1: Bright, 2: A little brighter, 3: Standard, 4: A little darker, 5: Dark - When CapNo refers to the text enhancement:
- This is enabled only for certain Canon DR scanners and
certain Epson scanners
(1) Canon DR scanner:
0: Text enhancement is not used (default), 1: Text enhancement is used, 2: Advanced text enhancement is used, 3: High speed text enhancement is used, 4,5: Advanced text enhancement II is used. (Value depends on the functions used)
(2) Epson scanners:
0: Character distinction is not used. (default), 1: Standard character distinction is used, 2: Strong character distinction is used
When CapNo refers to Brightness, Contrast, Gamma, Highlight,
Shadow, XResolution, YResolution, Rotation angle, Threshold,
XScaling, YScaling, and JPEG quality coefficient, SkipBlankPage
then the value returned will be the possible setting value for that
property.
Note: when ConType=6, the result will be the same as that returned
from the GetCapRange(GetCapRangeVariant).
- Regarding the string value set in the HalfToneList property
- When CapNo refers to HalfTone, the name of the HalfTone is
set.
When there is only one name "XXX,"
When there is more than one name "XXX,YYY, , "
XXX and YYY represent the name of the HalfTone, the name are separated by a comma with a comma at the end.
[Differences from the ImageKit7 ActiveX]
Rotation, OverScan, SkipBlankPage, and TextEnhancement values have
been added to CapNo